CD60 Capacitor Start Capacitor for Compressor

Product Details
Customization: Available
Type: Polypropylene Capacitor
Application: General Purpose, AC / Motor, Power, Lighting, Air Conditioner, High Voltage, Fan, Automobile
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2010-09-01
Management System Certification
ISO9001:2015
  • CD60 Capacitor Start Capacitor for Compressor
  • CD60 Capacitor Start Capacitor for Compressor
  • CD60 Capacitor Start Capacitor for Compressor
  • CD60 Capacitor Start Capacitor for Compressor
  • CD60 Capacitor Start Capacitor for Compressor
  • CD60 Capacitor Start Capacitor for Compressor
Find Similar Products

Basic Info.

Model NO.
CD60
Packaging Type
Surface Mount
Capacitance
>100uf
Structure
Fixed Capacitor
Manufacturing Material
Polypropylene
Electrolyte
Organic Medium
Usage
Low Frequency Coupling, High Frequency Coupling, Tuning, Filter, Low Frequency Bypass, High Frequency Bypass
Tuning
Polystyrene Capacitor
Filter
Aluminum Electrolytic Capacitor
Specification
CBB60
Trademark
SMILER
Origin
Guangdong, China (Mainland)
HS Code
8532100000
Production Capacity
50, 000 PCS Per Day

Packaging & Delivery

Package Size
37.00cm * 14.00cm * 28.00cm
Package Gross Weight
8.000kg

Product Description

 
 
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
Recommend Products view more >>
CD60 Capacitor Start Capacitor for Compressor
https://shunmeilai.en.
CD60 Capacitor Start Capacitor for Compressor
https://shunmeilai.en.
CD60 Capacitor Start Capacitor for Compressor
 
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
CD60 Capacitor Start Capacitor for Compressor
Type
CD60
Capacitance
1uF~80uF
Temperature
25/70/21,25/85/21
Tolerance
+_5%(J),+_10%(K),+10%(U),-5%(U)
Rated Voltage
150VAC~600VAC(50-60Hz)
CD60 Capacitor Start Capacitor for Compressor
 
The role and difference of starting capacitor and running capacitor

As we all know, single-phase AC motor is not like three-phase motor, it can turn up when given electricity, it needs a starting torque to rotate, and the clockwise and anti-clockwise of this torque determines the motor's steering, there are many ways to start, one of them is capacitor start, it is customarily called starting capacitor, single-phase motor needs it to turn up smoothly.

However, some single-phase motors have not only one capacitor, some motors have two capacitors, why is that? Because some motors are equipped with a starting capacitor and a running capacitor, what's going on?

Running capacitor: It is the alternating current shifted into the secondary winding to form an alternating magnetic field, and with the alternating magnetic field of the main winding to form an approximately circular elliptical rotating field. So he can be the same capacitor, but its function is different.

Either capacitor has a starting effect at the beginning of the motor start. But when the motor reaches about 75 [%] of the rated speed, the starting capacitor is only automatically disconnected by the centrifugal switch, while the running capacitor accompanies the motor to continue working. The process of starting the motor is actually the process of "phase listing". Because the single-phase motor is different from the three-phase motor, there is no phase difference, and no rotating magnetic field can be generated. The role of capacitor is to make the motor's starting winding current in time and space, ahead of the running winding 90 electrician angle, forming a phase difference. Among them, the running capacitor also plays the role of balancing the current between the main and secondary windings. The starting capacitor requires a withstand voltage of 250V or more because it works instantaneously for a short time, while the running capacitor requires a withstand voltage of 450V or more because it works for a long time all the time.

The starting capacitor is to energize the starting coil of a single motor when it is started and cut off after it is started,
while the running capacitor is to compensate the capacitance of the motor during operation, so the starting capacitor cannot be missing, while the running capacitor can be unnecessary.
The running capacitor is used when the press is working normally. The starting capacitor is used when the press is started and the running capacitor is used to start the press. After the press is turned up, the start capacitor is disconnected. The run and start capacitors are together, but one of the start capacitors is open, and the start capacitor is useless when the motor is turned on.

After Z, what is the difference between the start capacitor and the run capacitor? The capacity of start capacitor is large,
usually 2-5 times of run capacitor, while the capacity of run capacitor is small, and the difference between the two capacities is huge and easy to distinguish.

What is the main difference between the two?

Different status

Start capacitor: After the motor starts, the start capacitor is disconnected by the separation switch.
Running capacitor: After the motor starts, the running capacitor is involved in running with the starting coil.

Different capacity

Start capacitor: about 200 microfarads.
Running capacitor: about 20-30 microfarads.

Different roles

Starting capacitor: The starting capacitor is to make the starting coil of a single motor energized when starting and cut off
after starting.
Running capacitor: It makes the motor play capacitor compensation in running, starting capacitor can't be less, while running capacitor can be not used.
CD60 Capacitor Start Capacitor for Compressor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier